マインドマップギャラリー 酵素と補酵素
これは酵素と補酵素に関するマインド マップです。主な内容は、ビタミンと補酵素、酵素の分類と命名法、酵素活性の制御、酵素反応速度論、酵素学の紹介です。
2024-04-13 11:26:12 に編集されましたThis template, created with EdrawMind, provides a structured workflow for weekly coordination meetings focused on MEP (Mechanical, Electrical, Plumbing) pipeline layout. It follows a four-stage cycle: starting with Issue Identification (Clash Detection) to detect pipeline conflicts, moving to Meeting Agenda preparation to define discussion topics, then On-site Discussion to review and resolve issues on the construction site, and finally Resolution & Update to document solutions and track progress. This template can be reused to standardize MEP coordination processes, ensuring clear communication, efficient problem-solving, and smooth construction progress.
This template, created with EdrawMind, outlines a quarterly checklist for preparing materials for green building certification. It is divided into four sequential quarters: Q1 focuses on Basic Material Preparation, including collecting project approval documents and compiling self-assessment reports; Q2 covers Technical Data Improvement, such as organizing energy consumption calculation books and preparing green construction proof materials; Q3 involves On-site Inspection Preparation, including organizing construction process materials and verifying certification standards; and Q4 is for Formal Application, which includes completing online reporting and cooperating with expert on-site reviews. This template can be reused to systematically prepare for green building certification, ensuring all requirements are met and the process is efficient.
This template, created with EdrawMind, provides a comprehensive framework for daily monitoring of deep foundation pit construction. It covers six key monitoring areas: Retaining Wall Top Displacement, Settlement of Surrounding Buildings, Groundwater Level, Pit Bottom Heave, Support Axial Force, and Data Summary & Analysis. Each section specifies monitoring points, frequency, and warning values to ensure safety. The template can be reused to standardize monitoring practices, track structural stability, and trigger immediate alarms if warning thresholds are exceeded, thus mitigating risks during foundation pit construction.
This template, created with EdrawMind, provides a structured workflow for weekly coordination meetings focused on MEP (Mechanical, Electrical, Plumbing) pipeline layout. It follows a four-stage cycle: starting with Issue Identification (Clash Detection) to detect pipeline conflicts, moving to Meeting Agenda preparation to define discussion topics, then On-site Discussion to review and resolve issues on the construction site, and finally Resolution & Update to document solutions and track progress. This template can be reused to standardize MEP coordination processes, ensuring clear communication, efficient problem-solving, and smooth construction progress.
This template, created with EdrawMind, outlines a quarterly checklist for preparing materials for green building certification. It is divided into four sequential quarters: Q1 focuses on Basic Material Preparation, including collecting project approval documents and compiling self-assessment reports; Q2 covers Technical Data Improvement, such as organizing energy consumption calculation books and preparing green construction proof materials; Q3 involves On-site Inspection Preparation, including organizing construction process materials and verifying certification standards; and Q4 is for Formal Application, which includes completing online reporting and cooperating with expert on-site reviews. This template can be reused to systematically prepare for green building certification, ensuring all requirements are met and the process is efficient.
This template, created with EdrawMind, provides a comprehensive framework for daily monitoring of deep foundation pit construction. It covers six key monitoring areas: Retaining Wall Top Displacement, Settlement of Surrounding Buildings, Groundwater Level, Pit Bottom Heave, Support Axial Force, and Data Summary & Analysis. Each section specifies monitoring points, frequency, and warning values to ensure safety. The template can be reused to standardize monitoring practices, track structural stability, and trigger immediate alarms if warning thresholds are exceeded, thus mitigating risks during foundation pit construction.
酵素と補酵素
酵素学入門
酵素の化学的性質
酵素の定義
酵素の触媒特性
酵素と補酵素触媒の共通の性質
酵素は基質から生成物への変換を触媒します
酵素反応と非酵素反応の違い
酵素触媒のユニークな特性
酵素のその他の性質
酵素の分類と命名
酵素の分類
酵素の成分によると
単純な酵素
結合酵素
酵素補因子
補酵素
義足ベース
金属イオン
酵素の特性に合わせて
単量体酵素
オリゴメラーゼ
マルチ酵素システム
酵素によって触媒される反応に基づく
酸化還元酵素
転移酵素
加水分解酵素
リアーゼ
イソメラーゼ
リガーゼまたはシンターゼ
シンターゼとシンテターゼを区別する
酵素の命名
慣習的な命名法
基板に応じた名前
触媒反応の性質に応じて名前が付けられています
2つを組み合わせて名前を付けます
体系的な命名法
システムの命名
基板名
反応タイプ
4桁の酵素番号分類
ATPの例:グルコースホスホトランスフェラーゼ分類番号:E.C2.7.1.1
酵素反応速度論
酵素反応速度論の定義: 酵素反応速度とその影響因子
表現
影響を与える要因
酵素反応速度に対する基質濃度の影響
ミカエリス酵素の反応速度論
ミカエリス・メンテン方程式の解釈: Kcat、Kcat/Km、Vmax、Km
ミカエリス・メンテン方程式の双対性
ミカエリス・メンテン方程式の線形変換
ミカエリス酵素の二重逆数プロット
酵素阻害剤作用の動態
酵素阻害剤の種類
可逆的阻害剤
競合阻害剤
非競合阻害剤
抗競争阻害剤
不可逆的阻害剤
遺伝子特異的阻害剤
基質アナログ阻害剤
遷移状態アナログ阻害剤
自殺抑制剤
ミカエリス・メンテン酵素の速度論的特性に対する酵素阻害剤の影響
酵素活性の調節
酵素の「量的変化」
酵素の「量的変化」と「質的変化」の主な違い
アイソザイム
酵素の「質的変化」
アロステリック調整
共有結合修飾の制御
加水分解活性化
調節タンパク質の活性化または阻害
凝集と解離
ビタミンと補酵素
水溶性ビタミン
ビタミンB群
B1、B2、B3 (pp)、B6、パントテン酸、葉酸、ビオチン、リポ酸、B12
欠乏症
ビタミンC
体内の水酸化反応と抗酸化作用に参加します。
壊血病、抗酸化物質
脂溶性ビタミン
ビタミンA
ソース
生理機能
夜盲症
ビタミンD
くる病
ビタミンE
抗酸化
ビタミンK
補酵素として働くことができる唯一の脂溶性ビタミン
血液凝固ビタミン