The installation of anti-seismic brackets is best controlled after the installation of mechanical and electrical pipeline equipment, before project acceptance or before the start of the top surface engineering of the fine decoration project.
Edited at 2024-01-16 15:51:57This is a mind map about bacteria, and its main contents include: overview, morphology, types, structure, reproduction, distribution, application, and expansion. The summary is comprehensive and meticulous, suitable as review materials.
This is a mind map about plant asexual reproduction, and its main contents include: concept, spore reproduction, vegetative reproduction, tissue culture, and buds. The summary is comprehensive and meticulous, suitable as review materials.
This is a mind map about the reproductive development of animals, and its main contents include: insects, frogs, birds, sexual reproduction, and asexual reproduction. The summary is comprehensive and meticulous, suitable as review materials.
This is a mind map about bacteria, and its main contents include: overview, morphology, types, structure, reproduction, distribution, application, and expansion. The summary is comprehensive and meticulous, suitable as review materials.
This is a mind map about plant asexual reproduction, and its main contents include: concept, spore reproduction, vegetative reproduction, tissue culture, and buds. The summary is comprehensive and meticulous, suitable as review materials.
This is a mind map about the reproductive development of animals, and its main contents include: insects, frogs, birds, sexual reproduction, and asexual reproduction. The summary is comprehensive and meticulous, suitable as review materials.
Seismic bracket installation knowledge
1. It is not advisable to install the anti-seismic bracket too early
There are two obvious differences in the installation of seismic brackets and electromechanical pipeline load-bearing brackets:
First, the earthquake-resistant bracket is not used as a load-bearing bracket. (When finished load-bearing brackets are used together with anti-seismic brackets, such brackets also need to be load-bearing)
Second, the anti-seismic bracket can be installed only after the load-bearing bracket is installed.
2. Installation of anti-seismic brackets should not be too late
It is not good to install the anti-seismic brackets too late, as it will delay the construction period of the entire project. Some even fail to pass the acceptance test because the anti-seismic brackets are not installed according to specifications, causing the entire project to be delayed.
Therefore, it is particularly important to control the installation time node of the anti-seismic bracket.
In some fine decoration projects, the electromechanical pipelines are installed on the hoisting. Once the anti-seismic bracket is installed later than the ceiling keel, the construction will be extremely difficult, and irregular construction will also cause safety hazards.
3. How to control the installation node
Generally speaking, it is best if the seismic supports are installed close to the completion of the electrical duct work. As some projects have tight construction schedules, the installation of seismic brackets can be carried out according to buildings and floors. That is, the seismic brackets are installed immediately after the completion of each floor of electromechanical pipes. In this way, when the entire electromechanical project is completed, the seismic bracket project has also entered the final stage, ensuring that the entire The duration of the project.
Large sample drawing of anti-seismic bracket
water pipe
HVAC
bridge
On-site photos
To sum up, the installation of seismic supports is best controlled after the installation of electromechanical pipeline equipment, before project acceptance or before the start of the top surface work of the fine decoration project.