MindMap Gallery Safety valves for safety facilities [Regulations Summary]
As an important part of safety facilities, safety valves play the role of firewall and protective shield for equipment. Multiple regulations clearly stipulate the installation selection, installation requirements and installation location of safety valves. However, due to certain overlaps and duplications in regulations, individuals organize and group them to better meet legal compliance. requirements.
Edited at 2024-01-29 04:03:12Mappa mentale per l’analisi del controllo della gestione del portata di progetto. Tre sezioni principali: 1. WBS Scope Breakdown – scomposizione gerarchica del lavoro con dettaglio dello Scopo del progetto. 2. Scope Boundary / Exclusions – definizione chiara dei confini del progetto e di ciò che è escluso per evitare scope creep. Strumento ideale per project manager e team di controllo per mantenere allineamento e ridurre rischi.
Questo template, ideato con EdrawMind, è un modello completo per il miglioramento continuo del sistema di gestione della qualità, con una descrizione di circa 500 parole. È strutturato come un diagramma a lisca di pesce, strumento efficace per analizzare le cause principali dei problemi di qualità e definire le leve di controllo necessarie per risolverli. Il processo è organizzato in quattro fasi chiave: la prima è lo standard e la pianificazione, dove si definiscono gli obiettivi di qualità, i criteri di accettazione, i requisiti di prova e le porte di qualità (Quality Gate). La seconda fase analizza i processi e le porte di controllo, per garantire che ogni passaggio del lavoro segua i standard stabiliti. La terza fase riguarda l’esecuzione QA/QC, con la definizione di metodi di prova e ispezione, nonché regole per la gestione dei difetti e delle non conformità. L’ultima fase è il miglioramento e le azioni correttive e preventive (CAPA), insieme a una catena di audit per monitorare l’efficacia delle misure adottate. In basso, una tabella "Quality Gate" permette di tracciare ogni punto di controllo, con criteri specifici, metodi di prova, proprietario e stato di avanzamento. Grazie alla visualizzazione chiara e intuitiva di EdrawMind, questo strumento aiuta il team a identificare le cause root dei problemi di qualità, implementare azioni efficaci e mantenere un ciclo di miglioramento continuo, garantendo la qualità finale del prodotto o servizio.
Questo template, creato con EdrawMind, è un modello di piano di comunicazione ottimizzato, con una descrizione di circa 500 parole. È uno strumento chiave per evitare incomprensioni tra stakeholder, garantire la trasparenza e mantenere il team allineato agli obiettivi del progetto. Il modello è composto da tre elementi fondamentali e interconnessi: la matrice di comunicazione, la cadenza timeline e le regole di comunicazione/SLA. La matrice di comunicazione è una tabella dettagliata dove per ogni pubblico o stakeholder, si definisce il tipo di informazioni da condividere, lo scopo della comunicazione, il canale da utilizzare (email, riunioni, piattaforme di progetto), la frequenza, il proprietario responsabile, il formato e il percorso di escalazione in caso di problemi. La cadenza timeline è una linea temporale che definisce le scadenze delle comunicazioni chiave, garantendo che le informazioni siano condivise in momento opportuno e non si verifichino ritardi o omissioni. Le regole di comunicazione e gli accordi sul livello di servizio (SLA) definiscono le norme formali della comunicazione, come i tempi di risposta, il tono da adottare e le responsabilità di ciascun membro del team. Grazie alla struttura visuale di EdrawMind, questo template permette di pianificare la comunicazione in modo strategico, trasparente e efficiente, riducendo i rischi di cattiva informazione, migliorando la collaborazione e garantendo che tutti gli stakeholder siano informati e coinvolti nel progetto.
Mappa mentale per l’analisi del controllo della gestione del portata di progetto. Tre sezioni principali: 1. WBS Scope Breakdown – scomposizione gerarchica del lavoro con dettaglio dello Scopo del progetto. 2. Scope Boundary / Exclusions – definizione chiara dei confini del progetto e di ciò che è escluso per evitare scope creep. Strumento ideale per project manager e team di controllo per mantenere allineamento e ridurre rischi.
Questo template, ideato con EdrawMind, è un modello completo per il miglioramento continuo del sistema di gestione della qualità, con una descrizione di circa 500 parole. È strutturato come un diagramma a lisca di pesce, strumento efficace per analizzare le cause principali dei problemi di qualità e definire le leve di controllo necessarie per risolverli. Il processo è organizzato in quattro fasi chiave: la prima è lo standard e la pianificazione, dove si definiscono gli obiettivi di qualità, i criteri di accettazione, i requisiti di prova e le porte di qualità (Quality Gate). La seconda fase analizza i processi e le porte di controllo, per garantire che ogni passaggio del lavoro segua i standard stabiliti. La terza fase riguarda l’esecuzione QA/QC, con la definizione di metodi di prova e ispezione, nonché regole per la gestione dei difetti e delle non conformità. L’ultima fase è il miglioramento e le azioni correttive e preventive (CAPA), insieme a una catena di audit per monitorare l’efficacia delle misure adottate. In basso, una tabella "Quality Gate" permette di tracciare ogni punto di controllo, con criteri specifici, metodi di prova, proprietario e stato di avanzamento. Grazie alla visualizzazione chiara e intuitiva di EdrawMind, questo strumento aiuta il team a identificare le cause root dei problemi di qualità, implementare azioni efficaci e mantenere un ciclo di miglioramento continuo, garantendo la qualità finale del prodotto o servizio.
Questo template, creato con EdrawMind, è un modello di piano di comunicazione ottimizzato, con una descrizione di circa 500 parole. È uno strumento chiave per evitare incomprensioni tra stakeholder, garantire la trasparenza e mantenere il team allineato agli obiettivi del progetto. Il modello è composto da tre elementi fondamentali e interconnessi: la matrice di comunicazione, la cadenza timeline e le regole di comunicazione/SLA. La matrice di comunicazione è una tabella dettagliata dove per ogni pubblico o stakeholder, si definisce il tipo di informazioni da condividere, lo scopo della comunicazione, il canale da utilizzare (email, riunioni, piattaforme di progetto), la frequenza, il proprietario responsabile, il formato e il percorso di escalazione in caso di problemi. La cadenza timeline è una linea temporale che definisce le scadenze delle comunicazioni chiave, garantendo che le informazioni siano condivise in momento opportuno e non si verifichino ritardi o omissioni. Le regole di comunicazione e gli accordi sul livello di servizio (SLA) definiscono le norme formali della comunicazione, come i tempi di risposta, il tono da adottare e le responsabilità di ciascun membro del team. Grazie alla struttura visuale di EdrawMind, questo template permette di pianificare la comunicazione in modo strategico, trasparente e efficiente, riducendo i rischi di cattiva informazione, migliorando la collaborazione e garantendo che tutti gli stakeholder siano informati e coinvolti nel progetto.
safety valve
Safety valve selection
Full lift safety valve;
Exhaust gas or steam
The pressure storage tank safety valve should be selected as a full lift safety valve.
3.2 When discharging liquid, use a full-open or slightly open safety valve;
3.3 When discharging water vapor or air, a safety valve with a wrench can be used;
3.4 For gases with a set pressure greater than 3MPa and a temperature exceeding 235°C, a safety valve with a heat sink should be used to prevent the discharge medium from directly eroding the spring;
3.5 If the discharge medium is allowed to leak into the atmosphere, select an open bonnet safety valve; if the discharge medium is not allowed to leak into the atmosphere, select a closed bonnet safety valve;
3.6 When discharging highly toxic, highly corrosive, or extremely dangerous media, a bellows safety valve should be used;
3.7 In the case of high back pressure, use a back pressure balanced safety valve or a pilot valve controlled safety valve;
3.8 In some important occasions, it is sometimes necessary to install two safety valves as backup for each other. In some special occasions, safety valves and bursting discs can be used in series.
The pressure storage tank safety valve should be selected as a full lift safety valve. "Code for Design of Tank Areas for Petrochemical Storage and Transportation Systems" (SH/T3007-2014) 6.4.3;
Safety valve settings
The opening pressure (constant pressure) of a single safety valve should not be greater than the design pressure of the equipment. When multiple safety valves are installed on a piece of equipment, the opening pressure (constant pressure) of one of the safety valves should not be greater than the design pressure of the equipment; the opening pressure of other safety valves can be increased, but should not be greater than 1.05 times the design pressure of the equipment.
For safety valves that may be blocked or corroded by materials, a bursting disc should be installed in front of the safety valve or anti-blocking measures such as purging, heating or insulation should be taken on its inlet and outlet pipes.
A bursting disc should be installed in front of the safety valve of equipment with higher concentration of ethylene oxide. The inlet pipe of the bursting disc should be equipped with nitrogen seal, and the outlet pipe of the safety valve should be filled with nitrogen.
For reaction equipment with sudden overpressure or instantaneous decomposition of explosive hazardous materials, if the safety valve cannot meet the requirements, a bursting disc or bursting disc and detonation tube should be installed. The detonation tube mouth must face a safe direction without fire source; necessary Measures should be taken to prevent secondary explosions and fires
It is not suitable to install a safety valve
1.Heating furnace tube;
If there is a shut-off valve or control valve on the outlet pipe of the heating furnace, a safety valve should be installed upstream of the valve;
"Setting and Selection of Safety Valve" (HG/T 20570.2-95)
Explanation of the provision: If a safety valve is installed in the outlet pipe of the heating furnace, it is easy to get coked and blocked, and it is also difficult to deal with the hot oil once it is released. If a safety valve is installed in the inlet pipe, the furnace tube feed may be interrupted during discharge, causing other accidents. The prevention of overpressure accidents in heating furnaces is generally solved by strengthening management.
2. In the same pressure system, if there is a safety valve at the pressure source, the other equipment does not need to be equipped with safety valves;
Explanation of the provisions: In the same pressure system, such as the oil and gas cooling system at the top of the fractionating tower, if a safety valve is already installed at the top of the fractionating tower, the oil and gas heat exchanger, oil and gas cooler, oil and gas separator and other equipment at the top of the fractionating tower may no longer be equipped with a safety valve.
3. Cleaning steam should not be used as a pressure source.
Explanation of the provision: In process installations, steam is commonly used as the purging medium for equipment and pipelines. Although the steam pressure is sometimes higher than the design pressure of the equipment and pipelines being purged, due to the cooling, condensation and pressure reduction of the steam during the purging process, Moreover, the rear system of the line sweep is open and will not produce overpressure, so the line sweep steam is not used as a pressure source.
Safety valve should be installed
The following independent pressure systems, working conditions, equipment and facilities where overpressure may occur should be equipped with safety relief devices:
pressurized vessel
1. Pressure vessels with the maximum operating pressure at the top greater than or equal to 0.1MPa; (pressure relief of pressurized vessels)
Negative pressure container
2. Distillation towers, evaporation towers and stripping towers with the maximum operating pressure at the top greater than 0.03MPa (except those where the steam at the top of the stripping tower is passed into another distillation tower); (pressure relief from negative pressure vessels)
Pressurization equipment
3. The outlets of each section of the reciprocating compressor or the outlets of positive displacement pumps such as electric reciprocating pumps, gear pumps, screw pumps (except for those that have safety valves in the equipment itself) (pressure relief from booster equipment)
7. Steam generators and other steam-producing equipment or their outlet pipes;
9 Steam outlet pipe of the condensing turbine;
Medium overpressure
8. Low boiling point liquid (liquefied gas, etc.) containers or their outlet pipes;
5. Equipment where flammable gas or liquid expands when heated and may exceed the design pressure; (material pressure relief)
3. Equipment and pipeline systems where the accumulation of non-condensable gas generates overpressure; (gas phase pressure relief)
5. The cut-off valves at both ends are closed, and the liquefied hydrocarbons, Class A B, and B A liquid pipeline systems are thermally expanded or vaporized due to the influence of ambient temperature, sunlight radiation or heat tracing;
10. Low boiling point liquid enters a container containing high temperature liquid.
High and low series connection
4. When the equipment connected to the outlet of the blower, centrifugal compressor, centrifugal pump or steam reciprocating pump cannot withstand its maximum pressure, the outlet of the blower, centrifugal compressor, centrifugal pump or steam reciprocating pump; (high pressure connected to low pressure, high pressure Side pressure relief)
2. When there is no safety valve at the source of the pressure material of the container;
3 Containers and pipelines whose design pressure is less than the pressure at the pressure source;
10 In some cases, due to leakage of the pump outlet check valve, resulting in overpressure, a safety valve is installed on the pump inlet pipe;
Loss of temperature and overpressure
2. The cooling water or reflux is interrupted, or the reboiler inputs too much heat, causing overpressure in the gas phase pipeline at the top of the distillation tower; (abnormal pressure increase and decrease in temperature)
6. Cooling or stirring failure, catalytic impurities entering, reaction inhibitor interruption, causing the exothermic reaction to run out of control in the reactor or the piping system upstream of the shut-off valve at its outlet;
Internal leakage and overpressure
9. Pipeline rupture or leakage may cause overpressure on the low-pressure side of the heat exchanger or its outlet pipe;
Other overpressure
1 Independent pressure system (separated from other systems with shut-off valve). The system refers to full gas phase, full liquid phase or gas phase communication;
Independent pressure system: refers to a pressure system that is connected by one or more devices through pipelines without valves in the middle or that will not cause obstruction. Both ends are equipped with valves that can be isolated from other systems.
7 Overpressure parts caused by process accidents, automatic control accidents, power accidents, fire accidents and public engineering accidents;
6. Equipment with a maximum top operating pressure of 0.03~0.1MPa should be set according to process requirements. (Replenish)
4. In the outlet pipe of the thermal oil furnace, the upstream pipe of the shut-off valve or regulating valve;
No matter how good the heat transfer oil is, it will coke and form carbon after long-term high-temperature operation. Especially in the high-temperature area of the furnace tube and the hot area of the equipment, there is a high incidence of carbon formation, and carbon formation is also a normal phenomenon. The problem is that there must be scientific and reasonable treatment after carbonization. After carbonization, the flow pore size of the furnace tube becomes smaller, the heat transfer slows down, the pore size becomes sticky and the carbon foam of the heat transfer oil becomes thicker, and the flow rate of the heat transfer oil slows down. This causes the furnace tube wall to burn thin, and the boiler heats up slowly and the oil outlet pressure decreases. At this time, if the carbon deposits in the furnace tube are not cleaned in time, the furnace tube will burn out and bulge, and the color will turn black or blue. This is the most dangerous period. If it continues to operate, the pressure of the circulating pump will continue to increase, eventually causing the furnace tube to burst suddenly, with disastrous consequences.
6. If there is a shut-off valve or control valve on the outlet pipeline of the heating furnace, a safety valve should be installed upstream of the valve;
Note
Design fire protection standards for petrochemical enterprises (GB50160-2018) 5.51
"Fire Protection Standards for Engineering Design of Fine Chemical Enterprises" (GB 51283-2020)
"Setting and Selection of Safety Valve" (HG/T 20570.2-95)
"Pressure Vessels" (GB150.1-2011) 3.1